IEC60227, IEC60245, EN50525, GB2023,GB2013,IS694检测设备清单 Test Equipments List Of Cable and Wire
仪器信息|Tester Specifications:http://www.ag17.wang/cabletester/
IEC 60227-2 2.Edition(1997-11)+Am.1(2003-03) and additional tests according to IEC 60811 and IEC 60332 Polyvinylchloride insulated cables of rated voltages up to and including 450/750 V-TestMethods;
IEC60227-3 2.Edition (1993-02) + Am.1(1997-07) Polyvinyl chloride insulated cablesof rated voltages up to and including 450/750 V-Non sheathed cables for fixedwiring;
IEC60227-4 2. Edition (1992-03) + Am. 1 (1997-07)Polyvinyl chloride insulated cables of rated voltages up to and including450/750 V-Sheathed cables for fixedwiring;
IEC60227-5 Edition 3.0 (2011-09) Polyvinyl chloride insulated cables of ratedvoltages up to and including 450/750 V-Flexible cables (cords);
IEC60227-6 3. Edition (2001-06) Polyvinyl chloride insulated cables of ratedvoltages up to and including 450/750 V-Lift cables and cables for flexibleconnections;
IEC60227-7 1.Edition (1995-12)+Am.1(2003-03)+Edition 1.2-2012 Polyvinyl chloride insulated cables ofrated voltages up to and including 450/750 V-Flexible cables screened andunscreened with two or more conductors.
GB/T5023.2-2008 额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法
GB/T5023.3-2008 额定电压450/750V及以下聚氯乙烯绝缘电缆 第3部分:固定布线用无护套电缆
GB/T5023.4-2008 额定电压450/750V及以下聚氯乙烯绝缘电缆 第4部分:固定布线用护套电缆
GB/T5023.5-2008 额定电压450/750V及以下聚氯乙烯绝缘电缆 第5部分:软电缆(软线)
GB/T5023.6-2006 额定电压450/750V及以下聚氯乙烯绝缘电缆 第6部分:电梯电缆和挠性连接用电缆
GB/T5023.7-2008 额定电压450/750V及以下聚氯乙烯绝缘电缆 第7部分:二芯或多芯屏蔽和非屏蔽软电缆
Clause /章节 | Measurement/testing 测量/测试 | Testing /measuring equipment / material needed测试/测量设备/材料需求 | Tester Names/Types 仪器名称/型号 |
1.8 | Checking of the durability of colors and markings. | Piece of cotton wool or cloth and water | |
1.9 | Measurement of insulation thickness. | Profile projector or measuring microscope of at least 10 xmagnification. | |
1.10 | Measurement of sheath thickness. | Profile projector or measuring microscope of at least 10 xmagnification. | |
1.11 | Measurement of overall dimensions and ovality. | Profile projector, dial micrometer, vernier caliper, diameter measuringtape. | |
2.1 | Measuring bridge or equivalent electronical equipment. Thermometer ortemperature compensation to 20°C. | ||
2.2 | Voltage test carried out on completed cables. | AC voltage source (AC 0...2500 V). | |
2.3 | Voltage test on cores. | AC voltage source (AC 0...2500 V). | |
2.4 | Insulation resistance. | Insulation resistance tester with DC source between 80 V and 500 V.Heated water bath, thermometer. | |
3.1 | Flexing apparatus, pulleys made of metal with differentdiameters. | ||
3.2 | Bending test apparatus moving through 180° angel and flexing rate of 60per minute, - weight 0,5 kg, current load 0,1 A. | ||
3.3 | Snatch test. | Weight 0.5 kg, current load 0,1 A, rigid support. | |
3.5 | Static flexibility test. | Device for fixing the test sample. | |
3.6 | Tensile strength of the central heart of lift cables. | Freely hanging weight or a suitable mechanical strength testingmachine. | |
IEC 60811-1-1 Sub Clause 9.1 and IEC 60811-1-2 Sub Clause8.1 | IEC 60811-1-1 Sub Clause 9.1 and IEC 60811-1-2 Sub Clause8.1 | Tensile machine, equipment for punching dumb-bell test pieces andequipment for cutting or grinding the insulation or/and sheath to obtain 2parallel surfaces. | |
IEC 60811-3-2 | Air oven with natural air flow, airflow rate: 8...20 complete air changeper hour. | ||
IEC 60811-3-1 | Pressure test at high temperature for | Indentation device with a blade 0,7 ± 0,01mm wide, loads (weights),supports, air oven, microscope or profile projector with two decimalplaces. | |
IEC 60811-1-4 and | Cold bending test for insulation and sheath. | Cold bend test apparatus consisting essentially of a revolving mandreland guiding devices for the test pieces. | |
IEC 60811-1-4 | Cold elongation test for insulation and sheath. | Tensile machine with a cooling device or elongation machine installed ina cooling chamber. | |
IEC 60811-1-4 | Impact test at low temperature. | Impact test apparatus, refrigerator, hammers, pad of spongerubber. | |
IEC 60811-3-1 | Heat shock test for insulation and sheath. | Mandrels with different diameters. | |
IEC 60332-1 | Propane gas burner: a) 1 kW pre-mixed flame – b) diffusion flame, 3-sided metallic screen 1200 mm high, 300 mm wide and 450 mm deep with open frontand closed top and bottom. | ||
IEC 60811-3-2 | Thermal stability for insulation. | Glass tubes made of AR-glass closed at one end, length: 110 mm, outerdiameter approx. 5 mm, inner diameter 4,0 ± 0,5 mm. | |
IEC 60811-1-2 Sub Clause 8.1.4 | Test of non-contamination. | Tensile machine, equipment for punching dumb-bell test pieces equipmentfor cutting or grinding the insulation to obtain 2 parallel | |
Table 4, Ref. No.1.4 | Long term resistance of insulation to d.c. | Heated sodium chloride solution having a concentration of 10g/l bathwith thermoregulator, 220V d.c.supply, copper electrode, timer. | |
IEC 60811-1-2 Sub Clause 8.1.4 | Test of non-contamination. | Tensile machine, equipment for punching dumb-bell test pieces equipmentfor cutting or grinding the insulation to obtain 2 parallelsurfaces. | |
IEC 60811-3-2 Sub Clause 9 | Thermal stability for insulation and sheath. | Glass tubes made of AR-glass closed at one end, length: 110 mm, outerdiameter approx. 5 mm, inner diameter 4,0±0,5 mm. | |
IEC60227-6 | Flexing test apparatus, carriages reach a maximumrelative | ||
IEC 60096-1 | Transfer impedance for screened cables. | Equipment for measuring transfer impedance. | |
IEC 60811-1-2 | Tensile machine, equipment for punching dumb-bell testpieces, | ||
IEC 60811-2-1 | Mineral oil resistance of sheath or | Tensile machine, equipment for punching dumb-bell testpieces, |